When you need consistent water pressure across multiple floors or throughout a large building, booster pumps alone don't always tell the full story. Pairing them with pressure tanks creates a system that's smarter, more efficient, and better equipped to handle real-world demands. These integrated setups reduce wear on your equipment while keeping water flowing at the pressure your application needs.
We've seen integrated booster pump systems solve pressure problems in everything from high-rise apartments to hospitals and industrial facilities. The key is understanding how the components work together and what goes into sizing them correctly. Let's walk through what makes these systems tick and how to design one that fits your needs.

The setup includes a pump, motor, pressure tank (often with a bladder), and controller working as one unit. Water gets pulled into the expansion tank by the pump, compressing air inside the bladder to create highly pressurized water at the required level once it leaves the tank.
The expansion tank helps maintain water pressure without relying solely on pump operation, taking some of the requirement off the pumps while providing additional system performance benefits.When demand drops and pressure reaches the target level, pumps shut off. The compressed air in the tank keeps water pressurized and available. Pumps restart only when the tank depletes and pressure drops below the setpoint.
This back-and-forth cycle protects your pumps from constant cycling while meeting fluctuating demands throughout the day. For water treatment and HVAC applications, this reliability makes a real difference.

Without a hydropneumatic tank, pumps will short cycle on and off during no flow periods. Even a leaky faucet can cause pumps to operate unnecessarily without this pressurized reserve of water.That constant starting and stopping wears out motors, drives up energy costs, and shortens equipment life.
While pumps today are more robust than ever, they still wear down, require maintenance, and eventually fail. The lifespan of a pump can be dramatically improved by reducing its operation time and frequency.We've watched properly designed systems cut pump cycles by 60% or more compared to tankless setups.
Key advantages include:
Expansion tanks keep the pump from starting excessively due to small piping leaks in a building. Excessive starting shortens the life of the controls and the pump's motor, plus it's costly in terms of energy use.

Getting tank size right depends on two main factors: how long you want pumps to stay off during low demand, and where the tank sits relative to the pumps.
Sizing depends on the length of time the designer theorizes that the booster pumps should remain off in a no-flow condition. It's recommended that pumps stay off between 15 to 30 minutes (depending on the type of building) during periods of low demand to save energy and prevent short cycling. A hospital will typically need a larger tank to keep booster pumps off for the same amount of time as an apartment building where low usage periods are consistent.
Tank location matters too. Tanks placed on the roof or at the high point in the system can typically be smaller than those installed at the discharge of the pressure booster.
For a practical example: a 124 GPM system operating at 98 PSIG might need a 109-gallon tank for a 15-minute shutdown period.A rule of thumb for tank sizing is one gallon of drawdown for each gallon of pump capacity. If you have a pump capable of supplying 15 GPM, the tank should allow 15 gallons of drawdown—the amount of water the tank will expel before the pump needs to come on to replenish it.
Fully integrated domestic water booster systems are ideal pressure solutions for multi-residential and commercial buildings, available in Simplex, Duplex, Triplex or Quadraplex configurations, each fully customizable.
Simplex systems use a single pump and work well for smaller applications up to 125 GPM. They're simpler and less expensive but offer no redundancy.
Duplex setups include two pumps that alternate as lead and lag.In the event one pump cannot maintain pressure, the second pump will turn on to assist.These handle applications up to 350 GPM and provide backup if one pump needs maintenance.
Triplex and Quadraplex configurations serve larger buildings or facilities with highly variable demand.Smart Variable Frequency Drives automatically maintain set pressure while alternating lead-lag pump operation every 24 hours.This spreads wear evenly across all pumps.
Today's sophisticated booster systems integrate multiple multi-stage pumps and variable frequency drive-controlled motors, along with software that adjusts pump speed and the number of pumps in operation to meet frequently changing system demand. These systems are designed to deliver minimal pump output necessary to achieve performance—all without direct human intervention.
Variable frequency drives (VFDs) have changed how we approach booster system design.Expansion tanks are sometimes required by VFD manufacturers to ensure smooth operation, though tank sizing for VFDs should follow the manufacturer's recommendations.
VFD controlled systems can deliver the exact needed amount of water, ensuring only the needed energy is consumed. These systems have the advantage that the set point can be altered according to flow, ensuring energy loss due to resistance in pipes is reduced.
Constant speed systems with larger pressure tanks still make sense in certain applications.The installation of an "on-off" type pumping system should be considered when relatively long periods of pump-on or pump-off are anticipated. Pumps are activated only when pressure is inadequate.These setups often cost less upfront and prove simpler to maintain.
When optimizing reverse osmosis systems, either approach can work depending on feed pressure stability and production demands.
Location matters more than you might think.The size and location of the booster pump need to be coordinated with the architect. There should be sufficient clearance around the pump for maintenance and a viable path in and out of the building in the event it needs replacing.
A water booster pump is usually installed at the point where a municipal water line enters a building. It's commonly set to run at 30-50 psi and consists of a pump, motor, pressure tank, and controller.
Pressure relief valves play a safety role you can't skip.Highly pressurized water exiting the expansion tank can cause potential pressure surges that damage plumbing and lead to equipment failure. Pressure relief valves prevent such accidents by controlling and curtailing the pressure of water exiting the expansion tank.
It's good practice to install pressure gauges in various locations around the water system. The gauges provide the ability to check pressure in various locations around the building. If you find an unusual pressure reading at a point in the system, you could check various gauges to troubleshoot where the issue is coming from.
Compared to other major components of a water system, booster pumps generally require minimal maintenance. Maintenance is usually undertaken annually. The pumps will need replacing eventually—their design life is around 15 years.
Regular checks should cover:
A 100-gallon poly storage tank provides reliable water reserve, ideal for systems with inconsistent supply or backup requirements.Inspecting this reserve capacity quarterly catches problems before they affect service.
Integrated booster pump and pressure tank systems deliver reliable water pressure while protecting your investment. The tank reduces cycling, extends pump life, and smooths out pressure variations that users notice. Proper sizing based on building type, demand patterns, and pump location makes the difference between a system that works and one that works well.
Whether you're designing for a 3-story office building or a 20-floor residential tower, the principles stay the same: match the pump capacity to peak demand, size the tank for reasonable off-cycles, and configure controls that respond to actual usage patterns. Get these elements right, and you'll have a system that performs for years with minimal fuss.
For more information about our solutions and how we can help with your specific application, visit CNP Pump.
What's the main benefit of adding a pressure tank to a booster pump system?
Pressure tanks reduce pump cycling by maintaining water pressure through compressed air when demand is low. This extends pump life, cuts energy costs, and prevents short cycling that wears out motors and controls. The tank also provides a buffer against water hammer and supplies water during brief pressure drops or power fluctuations.
How do I calculate the right pressure tank size for my building?
Tank sizing depends on pump flow rate (GPM), system pressure range, and desired off-time during low demand. A common rule is one gallon of drawdown per gallon of pump capacity. For a 20 GPM pump, you'd need a tank providing 20 gallons of usable drawdown. Hospitals and 24/7 facilities typically need larger tanks than residential buildings with predictable low-usage periods.
Can I use an integrated booster system with variable frequency drives?
Yes, VFD systems often include pressure tanks for smooth operation and cycle protection. However, tank sizing for VFD applications should follow the manufacturer's specific recommendations rather than traditional sizing methods. VFD systems adjust pump speed to match demand in real-time, reducing the tank size needed compared to constant speed systems.
Where should I install the pressure tank in relation to the booster pumps?
Tanks installed at the discharge of the booster pumps typically need to be larger than those placed at higher elevations like rooftops. Location affects the pressure differential the tank experiences and its effective storage capacity. Consider accessibility for maintenance and coordination with your building's mechanical room layout when choosing placement.
How often do integrated booster systems need maintenance?
Most systems need annual maintenance including checking pressure tank pre-charge, inspecting check valves, testing controls, and verifying motor condition. Pressure gauges and tank bladders should be inspected quarterly. With proper maintenance, booster pumps typically last 15 years before replacement. Variable speed systems may have additional drive-specific maintenance requirements.

CNP integrates the advanced R&D technologies from Europe and America, with the most advanced industrial design concept in Western Europe, with the production experience of modern industrial clusters in North America, with the most efficient and energy-saving product structure research in Hangzhou, China.
With the application of information technology, CNP has built its own smart factory, taking the lead in the introduction of SAP resource management system, becoming one of the key units of the key construction project of "machine substitution" in Hangzhou, with the whole process of production information monitoring and tracking, applying laser welding technology to the manufacturing process of robot pump spare parts in depth, using progressive die technology to ensure the quality of the whole process of the parts, all of which greatly reduce the production and manufacturing cycle, provide an intelligent production and manufacturing basis for the pump production.
CNP was recognized as state-certified enterprise technology center in 2016. It is the highest evaluation level for technology center in China. Besides, CNP has been carrying some technical courses in 11/12/13th National Five-Year Plan.
CNP uses digital integrated intelligent control technology to create domestic advanced M2M mode, intelligent control technology.
It includes intelligent current stabilization system, intelligent vacuum suppression system, intelligent auxiliary control monitoring system, intelligent non-negative pressure full frequency control system and intelligent water hammer two-way elimination system.
China Headquarter
ADD:No. 1 Hengyi Road, Qianjiang development zone,
Yuhang District, Hangzhou, Zhejiang, China
Tel: +86-571-88637351 / 86397810 / 86397876
Fax: +86-571-86397809 / +86-21-62108123
E-mail: info@nanfang-pump.com
Site: http://www.cnppump.com
Export Marketing Director
Jason Wu
Mob: +86- 13588305880
E-mail: jason@nanfang-pump.com
CNP Mongolia & Bangladesh & Hong Kong
Regional Manager: Betty
Tel: +86-571-86397838
Mob: +86-18768130466
E-mail: betty@nanfang-pump.com
CNP Philippines & Taiwan & Japan & Singapore
Regional Manager: Rope
Mob: +86-13291808628
E-mail: rope@nanfang-pump.com
CNP Central Asian countries
Regional Manager:Cynthia
Mob: +86-18829580294
E-mail: Cynthia@nanfang-pump.com
CNP Thailand & Myanmar
Regional Manager: Clint
Mob: +86- 13588417527
E-mail: clintpan@nanfang-pump.com
CNP Vietnam & Cambodia & Laos & Australia
Regional Manager: Nils
Mob: +86-13013349974
E-mail: nils@nanfang-pump.com
CNP Middle East
Regional Manager: Joseph
Tel: +86-571-86397827
Mob: +86-177 9220 2251
E-mail: Joseph@nanfang-pump.com
CNP South America
Regional Manager: Samuel
Mob: +86-15536501430
E-mail: Samuel@nanfang-pump.com
CNP Africa & Iran & Turkey
Regional Manager: Jamet
Mob: +86-15267008188
E-mail: jametsun@nanfang-pump.com
CNP India
Regional Manager: Leo
Tel: +86-571-86397838
Mob: +86-13093716925
E-mail: leosong@nanfang-pump.com
CNP Indonesia
Regional Manager: Owen
Tel: +86-571-86397838
Mob: +86-18298330893
E-mail:owenhou@nanfang-pump.com
CNP Pakistan & Sri Lanka
Regional Manager: Stephon
Mob: +86-15202978981
E-mail: stephon@nanfang-pump.com
ADDRESS : No.46,Renhe Road,Renhe Street,Yuhang District,Hangzhou,China
EMAIL : info@cnppump.com
TEL:0571-88637351